Maintenance Schedule for LitePOWER 60KW Generator
|
|
HOURS |
|
| Engine Oil | 200 hours |
| Engine Oil Filter | 200 hours |
| Fuel Filter | 400 hours |
| Water Separator | 400 hours |
| In Line Fuel Filter | 400 hours |
| Air Filter Elements (2) | 800 hours |
| Hydraulic System Filter | 800 hours |
| Clean Radiator Externally | 1600 hours or 24 months |
| Normal environments refer to operation of the generator in normal conditions. Air quality, fuel quality, temperature and load all affect service frequency. Airborne containments will affect the air filter and radiator service requirements. Poor fuel, either from the source or due to storage, will affect the fuel filters. Load, either excessive or minimal, will affect the lube oil requirements. Inspection and testing are extremely important. If you have a question about performance, test unit with a load-bank. | |
PART NUMBERS |
|
| Engine Oil - Delo 15W40 or Rotella T 15W40 | |
| Engine Oil Filter - Fleetguard LF3345 or Napa 1602 or AC PF1017 | |
| Fuel Filter - Fleetguard FS 19617 new standard. (Old FF5052 or Napa 3358 or AC TP1067) | |
| Water Separator - Fleetguard FS1280 or Napa 3357 or AC T1068 | |
| In Line Fuel Filter - Fleetguard FS1251 or Napa 3472 (Some models use Racor R60P(Napa 3231) or Racor R45P) | |
| Air Filter, Main - Nelson 70334N or Donaldson P181057 or Fleetguard AF888M or Napa 2321 | |
| Air Filter, Safety - Nelson 70333N or Napa 6522 | |
| Hydraulic System Filter Lenz CP 752-30, Donaldson P551553, Napa 1553 | |
| Hydraulic System Fluid - ATF III. Note: Do not fill above bottom of screen. | |
| Belt, Blower - RMA #BX38 Graingers #6A124 | |
| Belt Number for 60KW Water Pump/Alternator - Belt Cummings 3288689 | |
Burrell Enterprises, Inc.
3526 Lakeview Parkway #177, Suite B, Rowlett, TX 75088
Phone: (972) 475-8111 - Toll Free (866) 474-8111 or (800) 474-8111 - bob@litepower.com